| Sl.No | Material / Product | Parameter Tested | Test Method |
|---|
| 1 | Corrugated Fiber Board | Moisture Content | IS 1060 (Part 5/Sec 2)/ISO 287 |
| 2 | Corrugated Fiber board | Mould growth test | IS 10176 (Cl. 8.4/Appendix B) |
| 3 | Corrugated Fiber Board | Abrasion Loss | IS 4006: Part 1 |
| 4 | Corrugated Fiber Board | Brightness | TAPPI T 452 |
| 5 | Corrugated Fiber Board | Bursting strength | TAPPI T 810; IS 1060: Part 7: Sec 1/ISO 2759: |
| 6 | Corrugated Fiber board | Closure | IS 6715 Cl. 9; IS 9313 Cl. 7 |
| 7 | Corrugated Fiber board | Combined internal dimension | IS 10212 Part 1 |
| 8 | Corrugated Fiber board | Construction | IS 10212 Part 1 |
| 9 | Corrugated Fiber Board | Edgewise compressive strength of corrugatedfiberboard (short column test) | TAPPI T 811 |
| 10 | Corrugated Fiber board | Finish | IS 10176 Cl. 5; IS 11844 Cl. 4; IS 12212 Cl. 5 |
| 11 | Corrugated Fiber board | Flap bend Test | IS 10176 Cl. 5.2; IS 2771 (Part 1/Cl. 7.3) |
| 12 | Corrugated Fiber Board | Flat crush test (flexible beam method) | TAPPI T 808 |
| 13 | Corrugated Fiber Board | Flat crush test of corrugated board (rigid supportmethod) | TAPPI T 825 |
| 14 | Corrugated Fiber board | Joint Strength | IS 2771 (Part 1) Cl. 7.4 |
| 15 | Corrugated Fiber board | Manufacture | IS 10176 Cl. 5; IS 11844 Cl. 4 |
| 16 | Corrugated Fiber board | Manufacturer's Joint | IS 9313 Cl. 5.2 |
| 17 | Corrugated Fiber board | Material | IS 10176 Cl. 4 |
| 18 | Corrugated Fiber board | Printability | IS 10176 Cl. 8.3; IS 9313 Cl. 9; IS 6715 Cl. 10 |
| 19 | Corrugated Fiber board | Reinforcement | IS 9313 Cl. 8 |
| 20 | Corrugated Fiber Board | Substance of the ComponentPapers after Separation | IS 7063 (Part 4) |
| 21 | Corrugated Fiber Board | Thickness | IS 1060 (Part 5/Sec 3)/ISO 534: |
| 22 | Corrugated Fiber board | Type of flute | IS 6715 |
| 23 | Corrugated Fiber Board | Water absorptiveness | TAPPI T 441 |
| 24 | Corrugated Fiber Board | Water Proofness | IS 4006 (Part 1) |
| 25 | Corrugated Fiber board | Workmanship | IS 12212 Cl. 5; IS 10176 Cl. 5; IS 11844 Cl. 4 |
| 26 | Corrugated Fiber Board Box | Body Joint | IS 11844 Cl. 4.4; IS 12212 Cl. 5.3 |
| 27 | Corrugated Fiber Board Box | Box Material | IS 6715 Cl. 3 |
| 28 | Corrugated Fiber Board Box | Combined internal dimension | IS 9313 Cl. 3.2 |
| 29 | Corrugated Fiber Board Box | Compression Test | IS 7028 (Part 6) |
| 30 | Corrugated Fiber Board Box | Construction of box | IS 9313 Cl. 5 |
| 31 | Corrugated Fiber Board Box | Dimension (Height) | IS 2771 (Part 1) |
| 32 | Corrugated Fiber Board Box | Dimension (Length) | IS 2771 (Part 1) |
| 33 | Corrugated Fiber Board Box | Dimension (Width) | IS 2771 (Part 1) |
| 34 | Corrugated Fiber Board Box | Dimensions and Tolerence | IS 12212 (Cl. 6); IS 10176 Cl. 6; IS 11844 Cl. 4.5 |
| 35 | Corrugated Fiber Board Box | Edgewise Crush Resistance (Unwaxed Edge Method) | IS 7063 (Part 2)/ISO 3037 |
| 36 | Corrugated Fiber Board Box | Flap bend Test | IS 11844 (Cl. 5.5); IS 12212 (Cl. 8.2); IS 9313 (Cl. 5.1) |
| 37 | Corrugated Fiber Board Box | Gross mass | IS 9313 (Cl. 3.2) |
| 38 | Corrugated Fiber Board Box | Height of Flute | IS 12212 (Cl. 7) |
| 39 | Corrugated Fiber Board Box | Inclined Impact Test | IS 7028 (Part 3) |
| 40 | Corrugated Fiber Board Box | Manufacture | IS 12212 (Cl. 5) |
| 41 | Corrugated Fiber Board Box | Manufacturer's Joint | IS 6715 (Cl. 6) |
| 42 | Corrugated Fiber Board Box | Material | IS 11844 (Cl. 3) |
| 43 | Corrugated Fiber Board Box | Materials | IS 12212 (Cl. 4); IS 9313 (Cl. 4) |
| 44 | Corrugated Fiber Board Box | No. of Ply/Type of Wa l Unit | IS 2771 (Part 1) |
| 45 | Corrugated Fiber Board Box | Puncture Test | IS 4006 (Part 2) |
| 46 | Corrugated Fiber Board Box | Random Vibration | ASTM D4728 |
| 47 | Corrugated Fiber Board Box | Ro ling Test | IS 7028 (Part 5) |
| 48 | Corrugated Fiber Board Box | Stacking Test using Static Load | IS 7028 (Part 1) |
| 49 | Corrugated Fiber Board Box | Style of Box | IS 10212 (Part 1); IS 9313 (Cl. 3.1); IS 6715 (Cl. 4.2); IS 11844 (Cl. 4) |
| 50 | Corrugated Fiber Board Box | Styles of Fibreboard Containers | IS 6481 |
| 51 | Corrugated Fiber Board Box | Type of Flute | IS 12212 (Cl. 7) |
| 52 | Corrugated Fiber Board Box | Type of Flutes | IS 2771 (Part 1) |
| 53 | Corrugated Fiber Board Box | Vertical Impact Drop Test | IS 7028 (Part 4) |
| 54 | Corrugated Fiber Board Box | Vibration Test at Fixed Low Frequency | IS 7028 (Part 2) |
| 55 | Corrugated Fiber Board Box | Water Spray Test | IS 7028 (Part 8) |
| 56 | Corrugated Fiber Board Drum | Stacking Test using Static Load | IS 7028 (Part 1) |
| 57 | Corrugated Fibreboard | Deflection | IS 4006 (Part 1/Cl. 6) |
| 58 | Corrugated Fibreboard | Drop test | ICAO Technical instructions(Cl. 6.4.3); IMDG CODE (Cl. 6.1.5.3) |
| 59 | Corrugated Fibreboard | Flexural resistance | IS 4006 (Part 1/Cl. 6) |
| 60 | Corrugated Fibreboard | Odour | IS 4006 (Part 2/Cl. 7) |
| 61 | Corrugated Fibreboard | Ply separation | IS 4006 (Part 2/Cl. 8) |
| 62 | Corrugated Fibreboard | Stack load test | IMDG CODE (Cl. 6.1.5.6) |
| 63 | Corrugated Fibreboard | Stacking test | ICAO Technical instructions(Cl. 6.4.6) |
| 64 | Corrugated Fibreboard | Styles of containers | IS 6481 |
| 65 | Corrugated Fibreboard | Thickness | IS 7063 (Part 1)/ISO 3034 |
| 66 | Corrugated Fibreboard | Water penetration | IS 4006 (Part 1/Cl. 8) |
| 67 | Corrugated Fibreboard | Water Resistance of Glue Bond by Immersion | IS 7063 (Part 3) |
| 68 | Paper board/Corrugated Fibre Board | Atmospheric Pre Conditioning + Atmospheric Conditioning +Random Vibration + Shock (Drop/Incline Impact) + Vibration(Fixed displacement/Random) | ISTA - 2C |
| 69 | Paper board/Corrugated Fibre Board | Atmospheric Pre Conditioning + Atmospheric Conditioning + Compression Conditioning (Machine/Static) + Shock (Drop) + Random Vibration | ISTA 3F |
| 70 | Paper board/Corrugated Fibre Board | Atmospheric Pre Conditioning + Atmospheric Conditioning + Compression Conditioning (Machine/Static) + Vibration(Fixed displacement/Random)+ Shock (Drop/Incline Impact) + Vibration(Fixed displacement/Random) | ISTA - 2B; ISTA - 2A |
| 71 | Paper board/Corrugated Fibre Board | Atmospheric Pre Conditioning + Atmospheric Conditioning + Shock (Drop) + Random Vibration + Shock (Rotational Edge Drop) + Shock (Rotational Flat Drop) + Shock (Concenrated impact) + Shock (Bridge impact) + Integrity (Leak test) | ISTA 3A |
| 72 | Paper board/Corrugated Fibre Board | Atmospheric Pre Conditioning + Atmospheric Conditioning + Shock (Free-Fa l Drop) + Random Vibration + Shock (Rotational Edge Drop) + Shock (Full Rotational Flat Drop) + Shock (Bridge impact) + Shock (Concenrated edge impact) + Integrity (Leak test) | ISTA 6-AMAZON.COM-SIOC (Type A) |
| 73 | Paper board/Corrugated Fibre Board | Atmospheric Pre Conditioning + Atmospheric Conditioning + Shock (Incline Impact) + Compression Conditioning (Machine/Static) + RandomVibration + Shock (Rotational Edge Drop) | ISTA 3E |
| 74 | Paper board/Corrugated Fibre Board | Atmospheric Pre Conditioning + Atmospheric Conditioning + Tip/Tip Over + Shock (Free-Fa l Drop) + Random Vibration + Shock (Concenrated impact) + Shock (Full Rotational Drop) + Shock (Bridge impact) + Shock (Concenrated edge impact) + Shock (Inclined Impact) | ISTA 3B |
| 75 | Paper board/Corrugated Fibre Board | Atmospheric Pre Conditioning + Compression Conditioning (Machine/Static) + Vibration(Fixed displacement/Random)+ Shock (Drop/Incline Impact) + Rotational Edge Drop | ISTA -1D |
| 76 | Paper board/Corrugated Fibre Board | Atmospheric Pre Conditioning + Compression Conditioning (Machine/Static) + Vibration (Fixed displacement/Random) + Shock (Drop/Incline Impact) | ISTA - 1C |
| 77 | Paper board/Corrugated Fibre Board | Atmospheric Pre Conditioning + Fixed Displacement + Shock (Drop/Incline Impact) | ISTA - 1A |
| 78 | Paper board/Corrugated Fibre Board | Atmospheric Pre Conditioning + Fixed vibration + Shock (Drop/Incline Impact) + Rotational Edge Drop | ISTA - 1B |
| 79 | Paper board/Corrugated Fibre Board | Compression Test (Apply and Hold) | ISTA - 1C; ISTA -1D; ISTA - 2A; ISTA - 2B; ASTM D 642; ISTA - 2C; ISTA 3E; ISTA 3F |
| 80 | Paper board/Corrugated Fibre Board | Compression Test (Apply and Release) | ISTA 3F; ISTA 3E; ISTA - 2B; ISTA - 2C; ISTA -1D; ISTA - 2A; ISTA - 1C; ASTM D 642 |
| 81 | Paper board/Corrugated Fibre Board | Compression Test (Weight and load spreader) | ISTA -1D; ISTA - 1C; ISTA - 2B; ISTA - 2A; ISTA - 2C; ISTA 3E; ISTA 3F |
| 82 | Paper board/Corrugated Fibre Board | Fixed Displacement Vibration | ISTA - 2C; ISTA - 2A; ISTA - 2B; ISTA - 1C; ISTA -1D; ISTA - 1B; ISTA - 1A |
| 83 | Paper board/Corrugated Fibre Board | Integrity Leak test | ISTA - 3A; ISTA 6-AMAZON.COM-SIOC (Type A) |
| 84 | Paper board/Corrugated Fibre Board | Random Vibration | ISTA 6-AMAZON.COM-SIOC (Type A); ISTA 3F; ISTA 3E; ISTA 3B; ISTA - 3A; ISTA - 2C; ISTA - 2B; ISTA - 2A; ISTA -1D; ISTA - 1C; ISTA -1G |
| 85 | Paper board/Corrugated Fibre Board | Shock (Free-Fa l Drop) | ISTA 3B; ISTA 6-AMAZON.COM-SIOC (Type A) |
| 86 | Paper board/Corrugated Fibre Board | Shock Bridge Impact | ISTA 3B; ISTA 6-AMAZON.COM-SIOC (Type A); ISTA - 3A |
| 87 | Paper board/Corrugated Fibre Board | Shock Concentrated edge Impact | ISTA 6-AMAZON.COM-SIOC (Type A); ISTA 3B |
| 88 | Paper board/Corrugated Fibre Board | Shock Concentrated Impact | ISTA 3B; ISTA - 3A |
| 89 | Paper board/Corrugated Fibre Board | Shock Drop | ISTA - 3A; ISTA - 2C; ISTA - 2A; ISTA - 2B; ISTA -1H; ISTA -1G; ISTA - 1C; ISTA -1D; ISTA - 1A; ASTM D 5276; ISTA - 1B; ISTA 3F |
| 90 | Paper board/Corrugated Fibre Board | Shock Full Rotational Drop | ISTA 3B |
| 91 | Paper board/Corrugated Fibre Board | Shock Full Rotational Flat Drop | ISTA 6-AMAZON.COM-SIOC (Type A) |
| 92 | Paper board/Corrugated Fibre Board | Shock Incline Impact | ISTA 3B; ISTA - 1B; ASTM D 880; ISTA - 1A; ISTA -1D; ISTA - 1C; ISTA -1G; ISTA - 2B; ISTA - 2A; ISTA - 2C |
| 93 | Paper board/Corrugated Fibre Board | Shock Incline Impact Test | ISTA 3E |
| 94 | Paper board/Corrugated Fibre Board | Shock Rotational Edge Drop | ISTA 3E; ISTA 6-AMAZON.COM-SIOC (Type A); ISTA - 3A; ISTA -1D |
| 95 | Paper board/Corrugated Fibre Board | Shock Rotational Flat Drop | ISTA - 3A |
| 96 | Paper/Paper board/Corrugated Fibre Board | Tip/Tip Over | ISTA 3B |
| 97 | paper, paperboard, Corrugated Fiber Board | Thickness | TAPPI T 411 |